Related Experiment Video
Updated: May 20, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Percutaneous minimally invasive instrumentation for traumatic thoracic and lumbar fractures: a prospective analysis
Antonio Krüger1, Katharina Rammler, Ewgeni Ziring
1University Hospital Giessen and Marburg, Location Marburg, Germany.
Abstract:
Open posterior instrumentation is still the standard procedure for unstable traumatic thoracic and lumbar fractures. There is a general tendency towards minimally invasive approaches in various surgical disciplines. The Sextant II Rod Insertion system is one of these. The authors prospectively studied this system in 51 patients with thoracic and lumbar fractures, between October 2007 and January 2011. Most fractures (31/51) were situated at the lumbar level. In 7 older patients the technique was combined with kyphoplasty and/or cement augmentation of the pedicle screws. The median operative time was 61 minutes (range: 26-130). The median fluoroscopy time was 132 seconds (range: 24-414). Most pedicle screws were correctly placed: 197 out of 204 screws. All fractures showed bony union after 6 weeks, but the multiaxial pedicle screws were not able to conserve the slight correction obtained peroperatively via positioning and longitudinal traction. Percutaneous minimally invasive stabilization of the spine needs further improvement.