Amikacin reverse iontophoresis: optimization of in vitro extraction

Fabio Marra1, Sara Nicoli, Cristina Padula

  • 1Dipartimento Farmaceutico, University of Parma, Viale delle Scienze 27/A, 43124 Parma, Italy.

Related Concept Videos

In Vitro Drug Dissolution: Alternative Methods01:17

In Vitro Drug Dissolution: Alternative Methods

Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions01:24

Drug Accumulation During Multiple Dosing: Intermittent IV Infusions

Intermittent intravenous (IV) infusion is a method of drug administration where medications are delivered over short infusion periods followed by intervals of no drug delivery. This approach helps to prevent sustained high drug concentrations in the bloodstream, reducing the risk of adverse effects associated with prolonged exposure. Unlike continuous infusion, steady-state concentrations may not be achieved during a single dosing cycle but can be reached through repeated...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Estimation of k and VD of Aminoglycosides01:20

Estimation of k and VD of Aminoglycosides

Aminoglycosides are a class of antibiotics used to treat various bacterial infections. Clinicians must determine the elimination rate constant (k) and volume of distribution (VD) to optimize therapeutic efficacy and minimize toxicity. The k value represents the rate at which the drug is removed from the body, and the VD reflects the degree to which the drug distributes into body tissues. Accurately estimating these parameters allows healthcare professionals to tailor drug dosing to individual...
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...