Real-time infrared thermography for ureter detection during hysterectomy
Roberto Angioli1, Corrado Terranova, Francesco Plotti
1Department of Obstetrics and Gynaecology, Campus Bio Medico, University of Rome, Rome, Italy. r.angioli@unicampus.it
Background:
Recognition of different anatomic structures might be difficult in the presence of diseases such as neoplasm or endometriosis that can subvert the anatomy. This can be a challenge for young surgeons approaching gynecologic surgery. The aim of the present study was to evaluate the effectiveness of infrared thermocamera to identify the anatomic structures in gynecologic surgery.
Materials And Methods:
From February 2010 to May 2011, consecutive patients who required abdominal hysterectomy were considered for eligibility. During a procedure for benign disease, we evaluated the temperature difference between the ureter and infundibulopelvic vessel (experiment A). In patients with gynecologic cancer, the thermal gradient was determined between the iliac vessels and the ureter (experiment B).
Results:
The data from 21 patients were recorded, 12 for experiment A and 9 for experiment B. We found a statistically significant difference between the ureter and vessels in both experiments (31.675°C ± 0.673°C for the ureter and 33.332°C ± 0.828°C for the infundibulopelvic vessel, P < 0.0001; 31.706°C ± 0.751°C for the ureter, 33.787°C ± 0.63°C for the iliac vein, and 33.784°C ± 0.639°C for the iliac artery, P < 0.0001).
Conclusions:
Infrared imaging allowed us to identify the anatomic structures in laparotomy, providing preliminary data for its application in laparoscopy.
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies II: Ultrasonography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Urologic Endoscopic Procedure: Cystoscopic Examination