Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Continuous noninvasive hemodynamic monitoring in decompensated heart failure
Marcelo Villaça Lima1, Marcelo Eidi Ochiai, Kelly Novaes Vieira
1Hospital Auxiliar de Cotoxó - Instituto do Coração, HC, FM, USP, São Paulo, SP, Brasil. villacalima@cardiol.br
Background:
The clinical and hemodynamic assessment at the bedside and the use of pulmonary artery catheter for the estimation of hemodynamic data have been used in decompensated heart failure. However, there are no data on the use of continuous noninvasive hemodynamic monitoring.
Objective:
To compare the data obtained through noninvasive hemodynamic monitoring with invasive ones in patients with decompensated heart failure and refractory to treatment.
Methods:
The non-invasive hemodynamic measurements were obtained through continuous monitoring of systemic blood pressure by the pulse wave model (Modelflow) and compared with measurements obtained by the passage of a pulmonary artery catheter, simultaneously.
Results:
A total of 56 measurements were performed in 14 patients studied on different days and time periods. The correlation index between systolic blood pressure measurements was r = 0.26 (95% CI = 0.00 to 0.49, p = 0.0492) and diastolic ones, r = 0.50 (95% CI = 0.27 to 0.67, p <0.0001). The correlation was r = 0.55 (95% CI = 0.34 to 0.71, p <0.0001) for cardiac index and r = 0.32 (95% CI = 0.06 to 0 53, p = 0.0178) for systemic vascular resistance.
Conclusion:
There was a correlation between the hemodynamic measurements when compared to noninvasive pulmonary artery catheter measurements. The continuous noninvasive hemodynamic monitoring may be useful for hospitalized patients with decompensated heart failure.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Heart Failure V: Medical Management
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiomyopathy II: Dilated Cardiomyopathy
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: