In vivo oxygen uptake into the human cornea
Sho C Takatori1, Percy Lazon de la Jara, Brien Holden
1Department of Chemical and Biomolecular Engineering, University of California, Berkeley, California 94720-1462, USA.
Purpose:
We provide a new procedure to quantify in situ corneal oxygen uptake using the micropolarographic Clark electrode.
Methods:
Traditionally, upon placing a membrane-covered Clark microelectrode onto a human cornea, the resulting polarographic signal is interpreted as the oxygen partial pressure at the anterior corneal surface. However, the Clark electrode operates at a limiting current. Hence, oxygen flux is directly detected rather than partial pressure. We corrected this misunderstanding and devised a new analysis to quantify oxygen uptake into the cornea. The proposed analysis is applied to new polarographic data for 10 human subjects during open-eye oxygen uptake.
Results:
Average open-eye corneal oxygen uptake over 10 subjects is approximately 11 μL/(cm(2) h), approximately five times larger than the average reported by researchers who invoke the original mathematical analysis. Application of the classical interpretation scheme to our experimental data also garners uptake values that are approximately a factor of three to five times smaller than those obtained with our new procedure.
Conclusions:
The classical procedure originally developed by Fatt and colleagues misinterprets the behavior of the Clark microelectrode. We corrected the analysis of the in situ polarographic technique to provide a simple yet rigorous procedure for analyzing both previous data in the literature and those newly obtained. Our proposed interpretation scheme thus provides a reliable tool for in vivo assessment of corneal oxygen uptake.
Related Concept Videos
Oxygen Transport in the Blood
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.