Related Experiment Video
Updated: May 20, 2026

Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
Published on: May 22, 2020
Analytical approach and occurrence for the determination of mass concentration of PCDD/PCDF and dl-PCB in flue gas
J Rivera-Austrui1, K Martínez, M A Adrados
1Laboratory of Dioxins, Environmental Chemistry Department, IDÆA-CSIC, J. Girona 18‐26, Barcelona 08034, Spain.
Abstract:
In this work, a reliable methodology for the simultaneous analysis of PCDD/PCDF and dioxin-like PCB (dl-PCB) in flue gas emissions collected using continuous sampling devices is proposed. The analytical scheme followed the minimum requirements described in the EU standard EN-1948:1,2,3,4 according to samples containing large amounts of dioxins and dl-PCBs or samples collected over a long period of time of about 4 weeks. Parameters, such as reproducibility, precision, limits of detection (LOD), limits of quantification (LOQ), extract aliquot size, analytical blanks, extraction efficiency, as well as the amount of internal standards required for an accurate determination, were assessed. The findings demonstrate the suitability of the proposed analytical scheme for the analysis of PCDD/PCDF and PCB in samples collected using long-term sampling devices. The analysis of five different 5% v/v sample aliquots reported %RSD values lower than 10% for all of the 29 congeners at both low and high levels. Similarly, %RSD values were 3.2 and 2.0 for the low level samples and 0.9 and 1.1%RSD for the high level extracts for PCDD/PCDF and dl-PCB, respectively expressed in total TEQ units. Re-extraction provided values less than 3%, expressed in TEQ. Based on blank analyses, LOD values of 100 pg I-TEQ for PCDD/PCDF and 10 pg WHO-TEQ for dl-PCB were achieved when 5% v/v aliquots were analyzed. Finally, the proposed analytical approach was tested with samples from a wide range of combustion processes such as hazardous and municipal waste incinerators, as well as cement kilns (with and without waste co-incineration).
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Overview

