Related Experiment Video
Updated: May 19, 2026

Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
Evaluation of a rapid analyte measurement platform for West Nile virus detection based on United States mosquito
Banugopan Kesavaraju1, Ary Farajollahi, Richard L Lampman
1Salt Lake City Mosquito Abatement District, Salt Lake City, UT, USA. banu@slcmad.org
Abstract:
The rapid analyte measurement platform (RAMP) system is an immunoassay test for West Nile virus (WNV) detection. Although reverse transcriptase-polymerase chain reaction (RT-PCR) methodology has been regarded as the gold standard for confirming WNV presence, usage of RAMP testing kits has increased in the past years. We collected RAMP test result data that were subsequently confirmed with RT-PCR methodology from mosquito control agencies to evaluate the efficacy of the RAMP testing. Results indicate that there are a high number of false positives (RAMP positive, RT-PCR negative) with RAMP testing. Correlation between RAMP unit values and RT-PCR cycle threshold values were varied depending on the primer/probe being compared. Comparison of RT-PCR results (on the same samples) between laboratories also indicates variation among the procedures and their potential to influence the RAMP testing efficacies. We discuss the potential issues and solutions that could prevent the high rate of false positives.