Novel chemosensor for the visual detection of copper(II) in aqueous solution at the ppm level
Vadapalli Chandrasekhar1, Sourav Das, Rajeev Yadav
1Department of Chemistry, Indian Institute of Technology Kanpur, Kanpur, India. vc@iitk.ac.in
Inorganic Chemistry
|August 8, 2012
Abstract:
A new water-soluble, multisite-coordinating ligand LH(7) was prepared by the condensation of tris(hydroxymethyl)aminomethane with 2,6-diformyl-p-cresol. LH(7) is a selective chemosensor for Cu(2+), under physiological conditions, with visual detection limits of 20 ppm (ambient light conditions) and 4 ppm (UV light conditions). LH(7) can also be used in biological cell lines for the detection of Cu(2+).
More Related Videos
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Complexometric Titration: Overview
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free indicator. The...