[Flow and inspiratory pressure characteristics of In-Check(tm) and training whistles]
Tetsuri Kondo1, Toshimori Tanigaki, Sakurako Kato
1Department of Medicine, Chigasaki-Tokushukai Hospital.
Background:
The optimal inhalation effort using dry powder inhalers (DPI's) varies with the specific inhaler. Accordingly, the device used for instruction in the proper use of the specific DPI should have physical characteristics similar to the actual DPI. However, the precision with which these devices mimic the actual DPI's has not been established.
Methods:
We measured mouthpiece pressure (PI) and flow through the In-Check with an added flow resistance (for DiskusTM, DiskhalerTM, PulmicortTM, HandihalerTM, and ClickhalerTM) and the training whistles (for Diskus, Pulmicort, SymbicortTM, TwisthalerTM) at different inhalation pressures.
Results:
Both the In-Check with an added flow resistance for individual DPI and the training whistles for each DPI had parabolic PI-flow relationships similar to the actual DPI. When a curve was drawn from direct readings of the In-Check scale, it fell consistently below that based on the pneumotachometer values. PI-flow curves of the actual DPI fell below both of the above curves. Among the same type of DPI, PI-flow relationships resembled each other, but one of 13 in the Diskus group demonstrated curves above and one of 6 in Pulmicort demonstrated curves below the others. The flows at which sounds were generated from the whistle were between 25-50 L/min.
Conclusions:
Both In-Check and training whistles had suitable PI-flow relationships. Flow readings taken directly from In-Check tended to be lower than the measured value. A few training whistles might generate sounds with efforts below the optimal one.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...