Related Experiment Video
Updated: May 19, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Diagnostic performance of planar scintigraphy using ⁹⁹mTc-MIBI in patients with secondary hyperparathyroidism: a
Carmelo Caldarella1, Giorgio Treglia, Alfredo Pontecorvi
1Department of Bioimaging and Radiological Sciences, Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Largo Agostino Gemelli 8, 00168 Rome, Italy. carmelocaldarella@yahoo.it
Objective:
Parathyroid scintigraphy using (99m)Tc-MIBI is not currently considered a valuable diagnostic tool for the localization of involved glands in patients with secondary hyperparathyroidism (SHPT). However, published data about its diagnostic accuracy are discordant and a meta-analysis about this topic is still lacking. The aim of our study is to meta-analyze the published data about the diagnostic performance of (99m)Tc-MIBI parathyroid scintigraphy in patients with SHPT.
Methods:
A comprehensive computer literature search of studies published in PubMed/MEDLINE, Scopus and Embase databases through September 2011 and regarding the diagnostic accuracy of (99m)Tc-MIBI parathyroid scintigraphy in patients with SHPT was carried out. Only articles in English language in which at least 10 patients with SHPT underwent planar (99m)Tc-MIBI parathyroid scintigraphy were selected. Pooled sensitivity, pooled specificity and area under the ROC curve on a per lesion-based analysis were calculated to measure the diagnostic accuracy of (99m)Tc-MIBI parathyroid scintigraphy in SHPT patients.
Results:
Twenty-four studies comprising 471 patients were included in this meta-analysis. The pooled sensitivity and specificity of (99m)Tc-MIBI parathyroid scintigraphy in detecting hyperplastic glands in SHPT patients were 58 % [95 % confidence interval (95 % CI) 52-65 %] and 93 % (95 % CI 85-100 %), respectively, on a per lesion-based analysis. Area under ROC curve was 0.75.
Conclusions:
In patients with SHPT and diffuse or nodular hyperplasia, planar parathyroid scintigraphy using (99m)Tc-MIBI has demonstrated an inadequate diagnostic accuracy. Therefore, it should not be considered as a first-line diagnostic imaging method in the pre-surgical detection of hyperplastic parathyroid glands.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
