Innovative green supercritical fluid chromatography development for the determination of polar compounds
Amandine Dispas1, Pierre Lebrun, Patrick Sassiat
1Laboratory of Analytical Chemistry, CIRM, Department of Pharmacy, University of Liège, 1 Avenue de l'Hôpital, B36, B-4000 Liège, Belgium. amandine.dispas@ulg.ac.be
Abstract:
In the context of green analytical chemistry, a supercritical fluid chromatography method was developed. In order to prove the potential of this technology, a worst case was selected, i.e. the separation of very polar compounds. For that purpose, an innovative methodology based on design of experiments (DoE) and design space (DS) was previously developed and successfully tested on liquid chromatography. For the first time, this methodology was applied to a supercritical fluid chromatography (SFC) separation. First, a screening design was used to select the stationary phase and the nature of the mobile phase based on a maximization of the number of peaks eluted and a minimization of the number of co-eluted peaks. Then, a central composite design with orthogonal blocks defined a set of experiments used to model the retention times of each peak at the beginning, the apex, and the end. The gradient slope, the isocratic plateau before the gradient, the temperature, and the concentration of trifluoroacetic acid (TFA) in the mobile phase were the potentially influential factors. The critical quality attributes (CQAs), i.e. the separation (S) between peaks of the most critical pair, and the analysis time were the criteria considered to assess the quality of the separation. The DS was computed as the multidimensional subspace where the probability for the separation and analysis time criteria to be within acceptance limits was higher than a defined quality level. The DS was computed propagating the prediction error from the modeled responses to the quality criterion using Monte Carlo simulations. The optimal condition was predicted at a gradient slope of 3.8% min(-1) to linearly modify the modifier proportion between 5 and 40%, an isocratic time of 3min, a concentration of TFA of 25mM, and a temperature of 60.5°C. This optimal condition was experimentally tested to confirm the prediction. Furthermore, chromatographic conditions included in the DS and on the limits of the DS were experimentally tested to assess the robustness of the developed SFC method.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...