Related Experiment Video
Updated: May 19, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
An exploratory, randomized, crossover MRI study of microbicide delivery with the SILCS diaphragm compared to a
Sara Pentlicky1, Mark Rosen, Patricia S Coffey
1University of Pennsylvania, Philadelphia, PA 19104, USA.
Background:
Microbicide gels studied for HIV prevention often are delivered via a single-use vaginal applicator. Using a contraceptive diaphragm such as the SILCS diaphragm for gel delivery could have advantages, including lower cost and additional pregnancy prevention.
Study Design:
We performed an exploratory, nonblinded, randomized, crossover study among healthy, sexually active, nonpregnant women. Using BufferGel, we evaluated three microbicide delivery methods for gel distribution and retention: SILCS single-sided gel delivery, SILCS double-sided gel delivery and a vaginal applicator (without SILCS). Magnetic resonance images were taken at baseline, after gel insertion, and immediately and 6 h after simulated intercourse. Three women completed all gel delivery methods described in this article.
Results:
Magnetic resonance imaging analysis indicated similar gel spread in the vagina among all three methods. SILCS single-sided gel application resulted in the most consistent longitudinal coverage; SILCS double-sided gel application was the most consistent in the transverse dimension.
Conclusions:
Gel coverage was similar with all three methods. These results suggest that the SILCS microbicide delivery system is comparable to vaginal applicators for delivery of gel products intravaginally.