Treatment of mandible fractures using resorbable plates with a mean of 3 weeks maxillomandibular fixation: a
David E Vázquez-Morales1, Donita Dyalram-Silverberg, Stewart K Lazow
1Department of Dental and Oral and Maxillofacial Surgery, Kings County Hospital Center/SUNY Downstate Medical Center, Brooklyn, NY 11209, USA. davidevazquez@hotmail.com
Purpose:
In this study, a 2.5-mm resorbable plating system (Inion CPS, Tampere Finland) was assessed for the fixation of mandibular fractures with 3 weeks of maxillomandibular fixation.
Patients And Methods:
Fifty mandibular fractures in 34 patients (32 males, 2 females) with a mean of 20.8 days of maxillomandibular fixation (MMF) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 8 × 2.5 mm monocortical resorbable screws. All patients were followed for a minimum of 6 weeks with an average long-term follow-up of 10 months. The incidence of soft tissue infection, nonunion, malunion, malocclusion, osteomyelitis, nerve injury, and tooth damage was prospectively assessed.
Results:
Primary bone healing was achieved in 100% of cases. Ten minor complications (20%) were observed: 5 soft tissue infections (10%), 4 plate dehiscences (8%), and 1 malocclusion (2%). No evidence of malunion, nonunion, osteomyelitis, plate fracture, or iatrogenic dental or nerve injury was noted; no readmission or reoperation was necessary.
Conclusion: