Related Experiment Video
Updated: May 19, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Real-time fit of a respirator during simulated health care tasks
Jessica Hauge1, Marc Roe, Lisa M Brosseau
1University of Minnesota, School of Public Health, Division of Environmental Health Sciences, Minneapolis, MN 55419, USA.
Abstract:
Fit is an important but difficult-to-predict feature of respirator performance. This study examined a new approach to measuring respirator performance using two continuous direct-reading particle-counting instruments in a simulated health care workplace. A pilot test was conducted with eight experienced health care professionals who passed a traditional quantitative fit test before performing three randomized 10-min health care scenarios (patient assessment [PA], IV treatment [IV], and wound care [WC]). Two TSI Portacount Plus (Model 8020) with N95 Companion (Model 8095) instruments were used to continuously measure 1-sec ambient particle concentrations inside and outside the respirator facepiece. A simulated workplace protection factor (SWPF) was calculated by dividing outside by inside concentrations. Data were log transformed and examined using analysis of variance (ANOVA) between subjects, scenario types, and scenario order. The GM SWPF for the eight subjects, three scenarios per subject, ranged from 172 to 1073 (GSD 1.7 to 3.5) and was significantly different for each subject. A multi-way analysis of variance showed no difference between the three scenario types (PA, IV, WC). There were differences by the order in which scenarios were performed: the third scenario SWPF was significantly different and higher than that of the first and second scenarios. All subjects passed the initial quantitative fit test with a fit factor of at least 100. Five subjects had fit factors greater than 200 and GM scenario SWPFs greater than 400. Three participants with initial fit factors less than 200 had GM scenario SWPFs ranging from 132 to 326. This pilot test demonstrates that it is possible to evaluate instantaneous respirator fit using two quantitative fit test instruments in a simulated health care environment. Results suggest that an initial fit test may be predictive of fit during simulated tasks and that one scenario may be adequate for measuring a simulated workplace protection factor. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a video for subject D activities overlaid with simulated workplace protection factor data.].
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...