Related Experiment Video
Updated: May 19, 2026

Laparoscopic Extracorporeal Knot-Tying for Uterine Vessel Occlusion during Hysterectomy with Cervical Cerclage in Large Uteri
Published on: September 12, 2025
Vaginal hemorrhage from transobturator sling controlled with QuikClot combat gauze
Samit A Patel1, Matthew Martin, Ingrid Chamales
1Madigan Army Medical Center, 9040 Jackson Avenue, Tacoma, WA 98431, USA.
Abstract:
A 42-year-old woman underwent an outside-in transobturator sling procedure, with subsequent venous hemorrhage. Two rolls of Combat Gauze were placed intravaginally and taken out on postoperative day 2 with good hemostasis. Despite careful technique, hemorrhage is a known complication of midurethral slings. Advanced hemostatic dressings may provide hemorrhage control and avoid the need for surgical intervention. After an extensive literature review, we present the first case of QuikClot Combat Gauze used as a hemostatic agent due to vaginal hemorrhage.
Related Concept Videos
Venous Thrombosis IV: Nursing Management
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...