Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Red blood cell deformability as a mechanobiological marker of CFTR dysfunction in cystic fibrosis.

iScience·2026
Same author

Correction: Tonon et al. 5-Azacytidine Downregulates the Proliferation and Migration of Hepatocellular Carcinoma Cells In Vitro and In Vivo by Targeting miR-139-5p/ROCK2 Pathway. <i>Cancers</i> 2022, <i>14</i>, 1630.

Cancers·2026
Same author

The <i>dilemma</i> of cancer biomechanics assessment: Living soft matter from a rheological perspective.

Materials today. Bio·2026
Same author

Author Correction: Defective CFTR induces aggresome formation and lung inflammation in cystic fibrosis through ROS-mediated autophagy inhibition.

Nature cell biology·2026
Same author

Concentrated Rhamnolipid Formulations: Bridging Chemodiversity to Structure, Flow Behavior, and Functionality.

ACS sustainable chemistry & engineering·2026
Same author

Coupled bulk and surface mechanisms lead to whey protein deposits under shear.

International journal of biological macromolecules·2026

Related Experiment Video

Updated: May 19, 2026

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes
13:57

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes

Published on: December 24, 2014

Flow reduction in microchannels coated with a polymer brush.

Luca Lanotte1, Stefano Guido, Chaouqi Misbah

  • 1University of Grenoble 1/CNRS, LIPhy UMR 5588, BP 87, 38041 Grenoble, France.

Langmuir : the ACS Journal of Surfaces and Colloids
|September 1, 2012
PubMed
Summary

Researchers designed polymer brush-coated microchannels. The "hairy" capillaries showed unexpectedly high flow reduction in water, exceeding standard models.

More Related Videos

Fabrication of Refractive-index-matched Devices for Biomedical Microfluidics
09:54

Fabrication of Refractive-index-matched Devices for Biomedical Microfluidics

Published on: September 10, 2018

Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications
08:38

Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications

Published on: January 16, 2018

Related Experiment Videos

Last Updated: May 19, 2026

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes
13:57

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes

Published on: December 24, 2014

Fabrication of Refractive-index-matched Devices for Biomedical Microfluidics
09:54

Fabrication of Refractive-index-matched Devices for Biomedical Microfluidics

Published on: September 10, 2018

Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications
08:38

Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications

Published on: January 16, 2018

Area of Science:

  • Fluid dynamics
  • Materials science
  • Surface chemistry

Background:

  • Microfluidic devices rely on precise control of fluid flow.
  • Polymer brushes are used to modify surface properties in microchannels.
  • Understanding flow behavior in "hairy" capillaries is crucial for microfluidic applications.

Purpose of the Study:

  • To design and fabricate microchannels coated with polymer brushes using the "grafting-from" technique.
  • To experimentally measure velocity profiles of water flow in these "hairy" capillaries.
  • To compare experimental results with theoretical predictions and geometric arguments.

Main Methods:

  • Fabrication of glass capillary microchannels coated with polymer brushes via "grafting-from" polymerization.
  • Experimental measurement of velocity profiles for pressure-driven water flow.
  • Analysis of flow reduction compared to bare capillaries.

Main Results:

  • The "hairy" capillaries exhibited significant flow reduction.
  • Observed flow reduction was greater than predicted by simple geometric models of reduced channel diameter.
  • The results also deviated from predictions based on poro-elastic boundary models.

Conclusions:

  • Polymer brushes in microchannels induce a flow reduction effect that is not fully explained by current models.
  • The "grafting-from" technique provides a viable method for creating functionalized microchannels.
  • Further research is needed to develop more accurate models for fluid flow in "hairy" microchannels.