A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
Published on: December 6, 2024
Emergency physician estimation of blood loss
Introduction:
Emergency physicians (EP) frequently estimate blood loss, which can have implications for clinical care. The objectives of this study were to examine EP accuracy in estimating blood loss on different surfaces and compare attending physician and resident performance.
Methods:
A sample of 56 emergency department (ED) physicians (30 attending physicians and 26 residents) were asked to estimate the amount of moulage blood present in 4 scenarios: 500 mL spilled onto an ED cot; 25 mL spilled onto a 10-pack of 4 × 4-inch gauze; 100 mL on a T-shirt; and 150 mL in a commode filled with water. Standard estimate error (the absolute value of (estimated volume - actual volume)/actual volume × 100) was calculated for each estimate.
Results:
The mean standard error for all estimates was 116% with a range of 0% to 1233%. Only 8% of estimates were within 20% of the true value. Estimates were most accurate for the sheet scenario and worst for the commode scenario. Residents and attending physicians did not perform significantly differently (P > 0.05).
Conclusion:
Emergency department physicians do not estimate blood loss well in a variety of scenarios. Such estimates could potentially be misleading if used in clinical decision making. Clinical experience does not appear to improve estimation ability in this limited study.
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.