Related Experiment Video
Updated: May 19, 2026

10:59
Determination of Lipid Raft Partitioning of Fluorescently-tagged Probes in Living Cells by Fluorescence Correlation Spectroscopy (FCS)
Published on: April 6, 2012
Tackling sample-related artifacts in membrane FCS using parallel SAF and UAF detection.
Christian M Winterflood1, Thomas Ruckstuhl, Nicholas P Reynolds
1Institute of Physical Chemistry, University of Zurich, Switzerland.
Summary
Measuring molecular diffusion in cell membranes is challenging due to complex cell shapes. This study presents a new method using supercritical angle fluorescence (SAF) and undercritical angle fluorescence (UAF) to improve diffusion measurement accuracy.
Area of Science:
- Biophysics
- Cell Biology
- Optical Methods
Background:
- Accurate molecular diffusion measurements in plasma membranes are crucial for understanding cell function.
- Cellular membrane complexity and plasticity pose significant challenges for techniques like fluorescence correlation spectroscopy (FCS).
- Non-ideal membrane geometry and intracellular fluorescence can introduce artifacts in diffusion measurements.
Purpose of the Study:
- To develop a method for identifying and correcting artifacts in molecular diffusion measurements caused by non-ideal cell membrane geometry.
- To enhance the accuracy of diffusion measurements in plasma membranes using fluorescence correlation spectroscopy.
Main Methods:
- Simultaneous measurement of fluorescence emitted above and below the critical angle at the specimen/glass interface.
- Generation of two laterally coincident detection volumes with different axial penetration depths.
- Analysis of the similarity between intensity tracks of supercritical angle fluorescence (SAF) and undercritical angle fluorescence (UAF).
Main Results:
- The presented method effectively identifies axial motion components arising from non-ideal membrane shapes.
- The similarity between SAF and UAF intensity tracks correlates with membrane flatness and intracellular fluorescence.
- This approach allows for the detection and potential correction of sample-related artifacts.
Conclusions:
- The developed method provides a reliable way to assess membrane geometry and reduce artifacts in diffusion measurements.
- This technique improves the accuracy and reliability of molecular diffusion studies in complex cellular environments.
- It offers a valuable tool for biophysical studies requiring precise membrane diffusion analysis.