Surface chemical and physical modification in stent technology for the treatment of coronary artery disease
Feroze Nazneen1, Grégoire Herzog, Damien W M Arrigan
1Tyndall National Institute, Life Sciences Interface, University College Cork, Lee Maltings, Cork, Ireland.
Insights
Coronary artery disease (CAD) treatments like stenting can be improved by modifying stent surfaces. Research explores chemical and physical surface changes to enhance compatibility and reduce complications.
Area of Science:
- Biomedical Engineering
- Cardiovascular Research
- Materials Science
Background:
- Coronary artery disease (CAD) is a leading cause of mortality worldwide, often treated with balloon angioplasty and stent implantation.
- Stent implantation, while effective, can lead to adverse vascular responses and complications.
- Improving stent-vascular compatibility is crucial for better patient outcomes.
Purpose of the Study:
- To review the merits and limitations of current coronary artery disease treatments, focusing on stenting.
- To explore research on modifying stent surfaces to improve biocompatibility and reduce pathophysiologies.
- To discuss chemical and physical modification strategies and their impact on vascular cells.
Main Methods:
- Review of existing literature on coronary artery disease treatments and stent surface modifications.
- Analysis of chemical (passive and active) and physical surface modification techniques.
- Discussion of in vitro studies on micro- and nanostructured surfaces and cellular responses.
Main Results:
- Stent surface modification offers potential to enhance stent-vascular compatibility.
- Both chemical and physical modifications can influence vascular cell responses.
- Micro- and nanostructured surfaces show promise in modulating cellular behavior.
Conclusions:
- Surface modification of coronary stents is a key research area for improving treatment efficacy.
- Combining chemical and physical modification strategies may offer synergistic benefits.
- Future research should focus on translating these modifications into clinical applications for better CAD management.
Abstract:
Coronary artery disease (CAD) kills millions of people every year. It results from a narrowing of the arteries (stenosis) supplying blood to the heart. This review discusses the merits and limitations of balloon angioplasty and stent implantation, the most common treatment options for CAD, and the pathophysiology associated with these treatments. The focus of the review is heavily placed on research efforts geared toward the modification of stent surfaces for the improvement of stent-vascular compatibility and the reduction in the occurrence of related pathophysiologies. Such modifications may be chemical or physical, both of which are surveyed here. Chemical modifications may be passive or active, while physical modification of stent surfaces can also provide suitable substrates to manipulate the responses of vascular cells (endothelial, smooth muscle, and fibroblast). The influence of micro- and nanostructured surfaces on the in vitro cell response is discussed. Finally, future perspectives on the combination of chemical and physical modifications of stent surfaces are also presented.
Related Concept Videos
Atherosclerosis III: Management
Angina IV: Management
Acute Coronary Syndrome IV: Interprofessional Care
Peripheral Artery Disease III: Interprofessional Care
Acute Coronary Syndrome I: Introduction
Coronary Artery Disease V: Interprofessional Care