Optometry-based general population survey of pupil ruff atrophy and ocular hypertension
Ghee S Ang1, Peter J Stevenson, Geoff Sargent
1Capital Eye Specialists, Wellington Hospital, Wellington, New Zealand.
Background:
To evaluate and describe the pupil ruff changes and relationship to intraocular pressure, pseudoexfoliation syndrome and glaucoma status in an optometric population in New Zealand.
Design:
Prospective cross-sectional survey of an optometric population.
Participants:
Six hundred and twenty subjects over 50 years old routinely attending the participating optometry practices. Exclusion criteria included previous intraocular surgery, ophthalmic laser, uveitis, angle closure and secondary glaucoma.
Methods:
Multicentre study involving 11 optometry practices in the Wellington region, New Zealand. The pupillary ruff and associated gonioscopy findings of study participants were graded based on the previously published Pupil Ruff Atrophy grading system. Parameters evaluated include pupillary ruff absence and abnormality, pseudoexfoliation material and trabecular meshwork pigmentation.
Main Outcome Measures:
Correlations between intereye Pupil Ruff Atrophy grading differences and inter-eye intraocular pressure and cup:disc ratio differences.
Results:
Six hundred and twenty subjects were included, with a mean age of 62.2 ± 9.1 years and mean intraocular pressure of 14.8 ± 3.4 mmHg. Four hundred and fourteen (66.8%) had bilateral pupil ruff changes and 12 (1.5%) had pseudoexfoliation. Inter-eye intraocular pressure asymmetry was significantly correlated with amount of missing pupillary ruff (r = 0.111; P = 0.022) and trabecular meshwork pigmentation (r = 0.147; P = 0.002). Inter-eye cup:disc ratio asymmetry was not correlated with any of the Pupil Ruff Atrophy grading parameters.
Conclusions:
Asymmetry of pupillary ruff absence and trabecular meshwork pigmentation was correlated with intraocular pressure asymmetry (but not with cup:disc ratio asymmetry) in a general optometric population setting in New Zealand.