Related Experiment Video
Updated: Aug 7, 2026

The Calibration and Use of Capacitance Sensors to Monitor Stem Water Content in Trees
Published on: December 27, 2017
A capacitance sensor for water: trace moisture measurement in gases and organic solvents
Shin-Ichi Ohira1, Kayoko Goto, Kei Toda
1Department of Chemistry, Kumamoto University, Kurokami 2-39-1, Kumamoto 860-8555, Japan. ohira@sci.kumamoto-u.ac.jp
Abstract:
The determination of water in various matrices is one of the most important analytical measurements. We report on a high-resolution capacitance-based moisture sensor utilizing a thin film of a perfluorosulfonate ionomer (PFSI)-H(3)PO(4) composite in a flow-through configuration, for both gas and liquid samples. Incorporation of H(3)PO(4) into a PFSI sensing film improved the limit of detection (LOD) (signal-to-noise ratio, S/N = 3) by a factor of 16 in the gas phase to 0.075% relative humidity (RH) (dew point = -56 °C). The response time was dependent on the sensing film thickness and composition and was as low as ∼60 ms. The temperature dependence of the sensor response, and its relative selectivity over alcohol and various other solvents, are reported. Measurement of water in organic solvents was carried out in two different ways. In one procedure, the sample was vaporized and swept into the detector (e.g., in a gas chromatograph (GC) without a column); it permitted a throughput of 80 samples/h. This is well-suited for higher (%) levels of water. In the other method, a flow injection analysis system integrated to a tubular dialysis membrane pervaporizer (PV-FIA) was used; the LOD for water in ethanol was 0.019% (w/w). We demonstrated the temporal course of drying of ethanol by Drierite; the PV-FIA results showed excellent correspondence (r(2) > 0.99) with results from GC-thermal conductivity detection. The system can measure trace water in many types of organic solvents; no reagent consumption is involved.
More Related Videos
Related Concept Videos
Amperometry: Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors