Related Experiment Video
Updated: May 18, 2026

Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020
Tribological evaluation of hydrogel articulations for joint arthroplasty applications
D Baykal1, J S Day, D J Jaekel
1School of Biomedical Engineering, Drexel University, USA. db434@drexel.edu
Abstract:
Characterizing the wear behavior of hydrogel articulations is problematic and a standardized method has not yet been developed. The aims of this study were to evaluate the wear resistance of hydrogel-on-hydrogel articulations and to assess the suitability of a submerged measurement technique as a practical and non-destructive method in quantifying their wear rates. Five hydrogel bearings were tested for 5 million cycles using a pin-on-disk tester. As the test progressed, the coefficient of friction increased (Spearman's rho=0.76; p<0.001) while the surfaces of the pins were burnished (Spearman's rho=-0.31; p<0.001) and those of the disks got rougher (Spearman's rho=0.19; p<0.01). Environmental scanning electron microscopy analysis showed no evidence of gross wear and revealed similar surface morphology between contacting and non-contacting regions of specimens. These results support the finding of low wear, which were -1.4±8.3 and 6.6±35.3mm(3)/MC based on submerged and wet weights, respectively. Pins displayed higher wear than disks based on submerged weights. This was anticipated since surfaces of pins were constantly under load and cross-shear while only a portion of the disk in contact with the pin was loaded at a given time. Wet weights, on the other hand, indicated higher wear for disks than pins. In addition, submerged weights yielded a lower standard error of the mean in wear rates than wet weights, 3.7 and 14.6mm(3)/MC, respectively. These results indicated that submerged weights were more suitable than wet weights in quantifying wear of hydrogels in spite of unwanted effects of swelling.
More Related Videos
09:48A Friction Testing-Bioreactor Device for Study of Synovial Joint Biomechanics, Mechanobiology, and Physical Regulation
Published on: June 2, 2022
12:22Synthesis of Thermogelling Poly(N-isopropylacrylamide)-graft-chondroitin Sulfate Composites with Alginate Microparticles for Tissue Engineering
Published on: October 26, 2016
Related Concept Videos
Structural Joints: Synovial Joints
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...