[Physical image properties of digital radiography systems in low dose range]
Hiroshi Kunitomo1, Katsuhiro Ichikawa, Ryo Higashide
1Department of Central Radiological Technology, Nagoya City University Hospital.
Abstract:
We measured physical image properties of a flat panel detector (FPD) system and a computed radiography (CR) system, targeting to a low dose range (reference dose: 2.58×10(-7) C/kg: to 1/20 dose). Input-output properties, pre-sampled modulation transfer functions (pre-sampled MTFs), and normalized noise power spectra for an FPD system equipped with a CsI scintillator (FPDcsi) and a CR system with an imaging plate coated with storage phosphor (CR) were measured at the low dose range for radiation quality of RQA3 (≍50 skV) and RQA5 (≍70 kV), and detective quantum efficiencies (DQEs) were calculated. In addition, in order to validate the DQE results, component fractions of Poisson and multiplicative and additive noise were analyzed using relative standard deviation analysis. The DQE values of FPDcsi were decreased with dose decrease, and contrarily to these, those of CR were increased. At the 1/10 and 1/20 doses for RQA3, the DQEs of FPDcsi and CR became almost the same. From the results of RSD analysis, it was proved that the main cause of DQE deterioration on FPDcsi are non-negligible additive (electronic) noise, and the DQE improvement on CR was caused by both of significant multiplicative (structure) noise and very low electronic noise. The DQE results were validated by comparing burger phantom images of each dose and radiation quality.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...