Related Experiment Video
Updated: May 18, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Clinical experience with intraoperative jugular venous oximetry during pediatric intracranial neurosurgery
Deepak Sharma1, Arunotai Siriussawakul, Neil Dooney
1Department of Anesthesiology & Pain Medicine, University of Washington, Seattle, WA, USA.
Aim:
To report our institutional experience with intraoperative jugular venous oximetry during pediatric intracranial surgery to guide anesthetic care.
Background:
The utility of intraoperative jugular venous oximetry in adults undergoing intracranial surgery is well known. However, there is a little information on its' application in children during intracranial surgery.
Methods:
After IRB approval, we examined patient, equipment, placement, and sampling characteristics for jugular bulb catheters in children aged <18 years who were monitored with jugular oximetry during elective intracranial surgery between 2006 and 2010. We also determined the prevalence of intraoperative cerebral desaturation (SjvO(2) < 55%), its causes, and the interventions based on jugular oximetry values.
Results:
Data from 19 children (10 males and nine females), aged 12 ± 1 years (range 7-17) who underwent craniotomy for arteriovenous malformation (AVM) resection (68%), tumor removal (21%), or aneurysm clipping (11%), were reviewed. We analyzed 88 coincident SjvO(2), PaCO(2), and mean arterial pressure data points. Eleven (58%) patients experienced at least one episode of cerebral desaturation. There were 25 (28%) episodes of cerebral desaturation, six of which we attributed to relative hypotension, four to hypocarbia, and 15 to a combination of both. There were no intraoperative or immediate postoperative (first 24 h) complications because of jugular oximetry.
Conclusion:
Findings from this series indicate that (i) intraoperative jugular venous oximetry in children is feasible in experienced hands, (ii) cerebral desaturation detected by jugular oximetry is common during pediatric intracranial procedures, and (iii) monitoring jugular venous saturation can impact anesthetic interventions to optimize cerebral physiology.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Increased Intracranial Pressure l: Introduction
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...