Related Experiment Video
Updated: May 18, 2026

Evaluating the Function of the Foot Core System in the Elderly
Published on: March 11, 2022
International scientific consensus on medical plantar pressure measurement devices: technical requirements and
Claudia Giacomozzi1, Noel Keijsers, Todd Pataky
1Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanità, Rome, Italy. claudia.giacomozzi@iss.it
Background:
Since 2006, the Italian National Institute of Health (ISS) has been conducting independent scientific activities to standardize the technical assessment of plantar pressure measurement devices (PMDs).
Material And Methods:
On the basis of the ISS results, in 2010 the Pedobarographic Group of the International Foot and Ankle Biomechanics community (i-FAB-PG) promoted a Consensus activity about the main technical requirements for the appropriate use of PMDs. The activity relied on a moodlebased on-line forum, documents exchange, discussions, reviews, meetings and a final survey.
Results:
The participation of clinical and technical researchers, users, and manufacturers, contributed to the delivery of the hereby reported recommendations which specifically regard Medical PMDs in the form of platforms.
Conclusions:
The i-FAB-PG community reached overall agreement on the recommendations, with a few minor objections which are reported and commented in the document. Relevance. The present document, the highest result achievable within a small scientific community, will hopefully represent the starting point of the wider process of establishing official international guidelines or standards, within scientific communities and standardization organizations.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...