Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Parallel Processing01:20

Parallel Processing

The brain processes sensory information rapidly due to parallel processing, which involves sending data across multiple neural pathways at the same time. This method allows the brain to manage various sensory qualities, such as shapes, colors, movements, and locations, all concurrently. For instance, when observing a forest landscape, the brain simultaneously processes the movement of leaves, the shapes of trees, the depth between them, and the various shades of green. This enables a quick and...
Accelerating Fluids01:17

Accelerating Fluids

When a fluid is in constant acceleration, the pressure and buoyant force equations are modified. Suppose a beaker is placed in an elevator accelerating upward with a constant acceleration, a. In the beaker, assume there is a thin cylinder of height h with an infinitesimal cross-sectional area, ΔS.
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Development and Usability Assessment of a Connected Resistance Exercise Band Application for Strength-Monitoring.

World academy of science, engineering and technology·2019
Same author

An Inverse Problems Approach to MR-EPT Image Reconstruction.

IEEE transactions on medical imaging·2015
Same author

FPGA Based High Speed Data Acquisition System for Electrical Impedance Tomography.

Journal of physics. Conference series·2014
Same author

Electrical property sensing biopsy needle for prostate cancer detection.

The Prostate·2013
Same author

Electrical impedance spectroscopy for prostate cancer diagnosis.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2013
Same author

A real-time electrical impedance sensing biopsy needle.

IEEE transactions on bio-medical engineering·2012
Same journal

Dissecting the integrated information of cardiovascular and cardiorespiratory systems at rest and during physiological stress.

Physiological measurement·2026
Same journal

Respiratory event type and duration modulate PPG waveforms in OSA.

Physiological measurement·2026
Same journal

Estimating changes in systolic blood pressure based on pulse wave morphology using paired segment comparison.

Physiological measurement·2026
Same journal

Small changes in hand height alter absorbance, but not pulsation, in the finger pulse plethysmograph.

Physiological measurement·2026
Same journal

A Comprehensive Inference-Time Augmentation Framework in Physiological Signals: Application to PPG-Based AF Detection.

Physiological measurement·2026
Same journal

Quantification of pendelluft in electrical impedance tomography data: opening Pandora's box? A literature review of analytical methods.

Physiological measurement·2026
See all related articles

Related Experiment Video

Updated: May 18, 2026

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

Multi-GPU Jacobian accelerated computing for soft-field tomography.

A Borsic1, E A Attardo, R J Halter

  • 1Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA. Andrea.Borsic@Dartmouth.edu

Physiological Measurement
|September 27, 2012
PubMed
Summary
This summary is machine-generated.

Accelerating 3D image reconstruction in soft-field tomography, like electrical impedance tomography (EIT), is crucial. This study significantly speeds up Jacobian computation using Graphics Processing Units (GPUs), reducing time from minutes to seconds.

More Related Videos

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Related Experiment Videos

Last Updated: May 18, 2026

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
08:16

Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

Published on: March 19, 2021

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Area of Science:

  • Medical Imaging
  • Computational Science
  • Applied Physics

Background:

  • Soft-field tomography relies on inverse problem formulation for image reconstruction.
  • Finite Element Models (FEMs) are used for complex anatomical shapes in 3D modeling.
  • Current 3D image reconstruction is computationally intensive, with Jacobian matrix computation dominating.

Purpose of the Study:

  • To accelerate the Jacobian computation for 3D soft-field tomography.
  • To investigate the use of single and multiple Graphics Processing Units (GPUs) for this acceleration.
  • To enable faster exploration of data and reconstruction parameters for applications like electrical impedance tomography (EIT).

Main Methods:

  • Optimized implementation of Jacobian computation on multi-core PC architecture.
  • Utilized single and multiple GPUs to accelerate Jacobian matrix computation.
  • Analyzed computational bottlenecks related to CPU-to-memory bandwidth.

Main Results:

  • Achieved acceleration factors of 20x on a single GPU and 50x on four GPUs.
  • Reduced Jacobian computation time for a fine 3D mesh from 12 minutes to 14 seconds.
  • Demonstrated that GPU memory bandwidth and parallelism overcome CPU limitations.

Conclusions:

  • GPU acceleration significantly reduces computational time for 3D image reconstruction in soft-field tomography.
  • This advancement is a key step towards achieving interactive reconstruction times.
  • The method is applicable to various soft-field imaging modalities using the adjoint method for Jacobian computation.