Phase-domain processing of optical coherence tomography images
Abstract:
In optical coherence tomography (OCT), images are usually formed from the envelope of the measured interference signal. Computation of the absolute magnitude of the signal for measurement of the envelope is a nonlinear process that destroys phase information. This study explores the idea of recording and processing the phase of the OCT interference signal before calculation of the magnitudes for display. Processing the partially coherent OCT signals in the complex domain provides the opportunity to correct phase aberrations responsible for speckle noise in OCT images. We describe an OCT system that incorporates a quadrature-demodulation scheme for accurate recording of the phase and amplitude of OCT signals from single or multiple detectors. A speckle-reduction technique that works in the complex domain, called the zero-adjustment procedure (ZAP), is investigated as an example of complex-domain processing. After demonstrating its speckle-correction properties mathematically and in numerical simulations, we apply ZAP to OCT images of living skin. The results show that ZAP reduces speckle contrast in regions where scatterer density is high and expands the range of gray values in the image. However, as presently implemented, ZAP tends to blur sharp boundaries between image features. © 1999 Society of Photo-Optical Instrumentation Engineers.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...