[Determination of kojic acid in foods using high performance liquid chromatography-tandem mass spectrometry]
Juan Huang1, Yan Liu, Tao Ding
1Animal, Plant and Food Inspection Center of Jiangsu Entry-Exit Inspection and Quarantine Bureau, Nanjing 210001, China. huang-juan@yeah.net
Abstract:
The quantification method for the determination of kojic acid in foods using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. For solid samples, the kojic acid was extracted with acetonitrile; for liquid samples, they were diluted with water, then deproteinized by the deposition with zinc acetate and potassium ferrocyanide. The analytes were determined by HPLC-MS/MS on a C18 column with 5 mmol/L ammonium acetate/formic acid solution as mobile phases. The analysis of kojic acid was performed under selected reaction monitoring (SRM) mode by selecting one parent ion and two daughter ions as qualitative ions with [13C6]-kojic acid as the internal standard, and the most abundant daughter ion as quantitative ion. The limits of quantification (S/N > 10) were 0.1 mg/kg for the solid samples, and 2.5 mg/kg for the liquid samples. The good linearity (r > 0.99) was achieved for the target compound over the range of 0.1 - 2.0 mg/L. The recoveries at three levels for kojic acid were from 72.6% to 114% with the relative standard deviations no more than 11.4%. The method is simple and practical, and can be applied to most of matrices which may contain kojic acid as food additives. It can meet the qualitative and quantitative requirements for import and export foods.
More Related Videos
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020
10:30A Generalized Method for Determining Free Soluble Phenolic Acid Composition and Antioxidant Capacity of Cereals and Legumes
Published on: June 10, 2022
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Spectroscopy of Carboxylic Acid Derivatives
In the...
NMR and Mass Spectroscopy of Carboxylic Acids
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the disappearance of the acidic...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...