Related Experiment Video
Updated: May 18, 2026

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape
I Larrabide1, M L Aguilar, H G Morales
1Networking Biomedical Research Center on Bioengineering, Biomaterials and Nanomedicine, Barcelona, Spain. ignacio.larrabide@upf.edu
Background And Purpose:
Effects of blood flow modification by flow diverters are observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to further understand the potential roles of intra-aneurysmal blood pressure changes and aneurysm morphologies, 23 patients were studied by numeric simulation.
Materials And Methods:
3D imaging of aneurysms of different sizes and shapes, all located at the supraclinoid segment of the ICA (n=23), was prepared for CFD simulations. Hemodynamic variables were calculated for conditions before and after virtual FD implantation, reconstituting a vessel wall scaffold across the aneurysm neck. WSS, velocity, residence time, turnover time, and intra-aneurysmal pressure were assessed statistically.
Results:
After placement of FDs, significant reductions inside the aneurysm were observed for most hemodynamic variables (P<.01) except mean intra-aneurysmal pressures. For minimum/maximum intra-aneurysmal pressure values, small but significant changes were found; however, they were considered too small to be of relevance.
Conclusions:
Calculations in 23 cases did not reveal significant intra-aneurysmal mean or peak pressure changes, indicating a minor role of pressure changes in the rare event of secondary ruptures after FD use. Other hemodynamic variables (WSS and velocity) exhibited more significant changes, indicating their role in intra-aneurysmal thrombus formation. Size-dependent, significantly higher reduction in WSS (P=.069) and velocity (P=.013) was observed in small aneurysms compared with larger ones. When it came to shape, there were significantly higher reductions in WSS (P=.055) and velocity (P=.065) and a significantly higher increase in turnover time in fusiform aneurysms compared with saccular aneurysms.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
09:32Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model
Published on: February 23, 2020
Related Concept Videos
Aneurysm I: Introduction
Aneurysm III: Interprofessional Care
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...
Increased Intracranial Pressure ll: Pathophysiology
Diverticular Disease of the Colon
Applications of Integration to Find Blood Flow