Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pulmonary Function Tests01:25

Pulmonary Function Tests

Pulmonary Function Tests (PFTs)
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies01:27

Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies

Assessing and diagnosing Chronic Obstructive Pulmonary Disease (COPD) involves a detailed approach that includes a comprehensive review of medical history, physical examination, and a variety of diagnostic tests. This thorough evaluation is essential to ensure an accurate diagnosis and guide effective management strategies.
Medical History
Assessment of Diffusion and Perfusion01:17

Assessment of Diffusion and Perfusion

Understanding and evaluating diffusion and perfusion is critical in assessing a patient's respiratory and circulatory health. These processes play key roles in maintaining the body's internal environment, ensuring that tissues receive adequate oxygen while waste products are efficiently removed.
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Exercise Stress Test01:26

Exercise Stress Test

Introduction
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Pulse Oximetry01:24

Pulse Oximetry

Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Components of Physical Fitness in Adults: A Roundtable Statement by the American College of Sports Medicine.

Medicine and science in sports and exercise·2026
Same author

Why quality of life outcomes matter for children with heart disease?

Annals of pediatric cardiology·2026
Same author

Physical activity phenotypes in endometriosis using unsupervised learning via functional mixture models.

BMC women's health·2025
Same author

Response to Letter to the Editor CLBP RCT-GSJ-25-1265.

Global spine journal·2025
Same author

Response to Letter to the Editor CLBP RCT-GSJ-25-1283.

Global spine journal·2025
Same author

Understanding the effectiveness of mHealth interventions incorporating behaviour change techniques in reducing sitting time in older adults: a protocol for a systematic review and meta-analysis.

BMJ open·2025
Same journal

Weighted Gene Co-expression Network Analysis of Early-Life PM₂.₅-Exposed Lung Transcriptome Identifies Key Gene Modules and Hub Genes Associated with Developmental Programming of COPD Vulnerability.

Respiratory physiology & neurobiology·2026
Same journal

Physiological responses during a maximal dry static breath-hold in a world champion freediver.

Respiratory physiology & neurobiology·2026
Same journal

Intermittent Hypoxemia in Preterm Infants: Glial Fibrillary Acidic Protein as a Potential Brain Injury Biomarker.

Respiratory physiology & neurobiology·2026
Same journal

Asymmetry of thoracic expansion in hemiplegic stroke and its relationship with physical function and percent vital capacity: A cross-sectional study.

Respiratory physiology & neurobiology·2026
Same journal

Evaluating the shape of the expiratory flow volume curve in asymptomatic ex-smokers.

Respiratory physiology & neurobiology·2026
Same journal

Emphysema and airway disease synergistically impair exercise tolerance in smokers: A CT-based study.

Respiratory physiology & neurobiology·2026
See all related articles

Related Experiment Video

Updated: May 18, 2026

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
09:33

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise

Published on: December 19, 2024

Optoelectronic plethysmography compared to spirometry during maximal exercise.

Aimee M Layton1, Sienna L Moran, Carol Ewing Garber

  • 1Department of Biobehavioral Sciences, Teachers College, Columbia University, 525 120th Street, New York, NY 10027, USA. aml2135@columbia.edu

Respiratory Physiology & Neurobiology
|October 2, 2012
PubMed
Summary
This summary is machine-generated.

Optoelectronic plethysmography (OEP) and spirometry provide comparable tidal volume (Vt) measurements during maximal exercise. These methods show high correlation and insignificant differences, validating OEP as a reliable tool for exercise physiology research.

More Related Videos

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
04:20

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure

Published on: October 1, 2019

Related Experiment Videos

Last Updated: May 18, 2026

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
09:33

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise

Published on: December 19, 2024

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
04:20

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure

Published on: October 1, 2019

Area of Science:

  • Exercise Physiology
  • Respiratory Mechanics
  • Biomedical Engineering

Background:

  • Accurate measurement of tidal volume (Vt) is crucial for understanding respiratory responses during physical activity.
  • Optoelectronic plethysmography (OEP) offers a non-invasive method for assessing breathing patterns.
  • Spirometry is a standard tool for pulmonary function testing, but its application during dynamic exercise requires validation.

Purpose of the Study:

  • To compare simultaneous measurements of tidal volume (Vt) using optoelectronic plethysmography (OEP) and spirometry.
  • To quantify differences between OEP and spirometry during maximal cycling exercise.
  • To assess the reliability of OEP for measuring Vt in an exercise context.

Main Methods:

  • Thirty healthy participants underwent a maximal cycling exercise test.
  • Simultaneous measurements of tidal volume (Vt) were collected using OEP and spirometry.
  • Data were analyzed using linear regression and Bland-Altman analysis at submaximal and maximal exercise intensities.

Main Results:

  • Both methods demonstrated very good correlation for Vt measurements during submaximal (R=0.963) and maximal exercise (R=0.982).
  • Bland-Altman analysis revealed minimal discrepancies between OEP and spirometry, with percentage differences of -2.0 ± 7.2% at submaximal and -2.4 ± 3.9% at maximal exercise.
  • High common variance was observed (SM R(2)=0.928, M R(2)=0.983), indicating substantial agreement between the two techniques.

Conclusions:

  • Tidal volume (Vt) measurements obtained by OEP and spirometry during exercise are highly correlated.
  • The observed differences between OEP and spirometry measurements are statistically insignificant.
  • OEP is a valid and reliable method for assessing tidal volume during maximal exercise testing.