Related Experiment Video
Updated: May 18, 2026

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
Published on: June 12, 2016
Volume flow calculations on gas leaks imaged with infrared gas-correlation
Jonas Sandsten1, Martin Andersson
1Department of Physics, Lund Institute of Technology, P.O. Box 18, SE-221 00 Lund, Sweden. jonas.sandsten@insatnet.nu
Abstract:
Two methods for volume flow calculation from images of methane leakages to the atmosphere are presented. The images contain calibrated gas concentration × path length pixel information, and are processed with a block matching method and a theoretical velocity field method. Results from known methane flow in two laboratory setups and one unknown real leakage from a gas processing plant are compared with the image processing methods. The methods are generic and can be implemented in common infrared systems for gas visualization. This work provides a new tool for estimating and reporting volume flow emissions from gas processing plants to the authorities.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
pV-Diagrams
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Real Gases: Effects of Intermolecular Forces and Molecular Volume Deriving Van der Waals Equation
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
The Joule and Joule–Thomson Experiments