Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging
R C Semelka1, E Tomei, S Wagner
1Department of Radiology, University of California, San Francisco 94143.
Radiology
|March 1, 1990
Summary
Cine magnetic resonance (MR) imaging provides reproducible measurements of left ventricular (LV) dimensions. This study found good interstudy reproducibility for LV mass, volume, and ejection fraction in healthy subjects.
Area of Science:
- Cardiovascular Imaging
- Medical Physics
- Radiology
Background:
- Accurate measurement of left ventricular (LV) dimensions is crucial for assessing cardiac function.
- Reproducibility of measurements is essential for reliable clinical interpretation and longitudinal studies.
- Cine magnetic resonance (MR) imaging is a key modality for cardiac assessment.
Purpose of the Study:
- To evaluate the reproducibility of ventricular dimension measurements using cine MR imaging.
- To determine interobserver and interstudy variability for key LV parameters.
- To assess the reliability of cine MR imaging for quantitative cardiac analysis.
Main Methods:
- 11 healthy subjects underwent cine MR imaging on two separate occasions.
- Two blinded reviewers analyzed the MR images.
- Measurements included LV mass, end-diastolic volume, end-systolic volume, ejection fraction, and systolic wall stress.
Main Results:
- LV mass demonstrated good reproducibility (3.6%-3.8% variability).
- LV volumes and ejection fraction showed acceptable interstudy variability (0.9%-9.7%).
- End-systolic wall stress exhibited the largest variability (11.1%-13.5%), primarily due to arterial pressure fluctuations.
Conclusions:
- Anatomic and functional measurements derived from cine MR images are reproducible between studies.
- The direct derivation of measurements from full cardiac cine MR images contributes to high reproducibility.
- Cine MR imaging is a reliable tool for quantitative assessment of left ventricular parameters.