Related Experiment Video
Updated: Dec 29, 2025

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Severe intraoperative bronchospasm treated with a vibrating-mesh nebulizer
Leonard R Golden1, Helen Ann DeSimone, Farhad Yeroshalmi
1Chairman, Department of Anesthesiology, Jacobi Medical Center, Bronx, NY, USA.
Abstract:
Bronchospasm and status asthmaticus are two of the most dreaded complications that a pediatric anesthesiologist may face. With the occurrence of severe bronchospasm and the inability to ventilate, children are particularly vulnerable to apnea and ensuing hypoxia because of their smaller airway size, smaller lung functional residual capacity, and higher oxygen consumption rates than adults. Nebulized medication delivery in intubated children is also more difficult because of smaller endotracheal tube internal diameters. This case demonstrates the potentially lifesaving use of a vibrating-mesh membrane nebulizer connected to the anesthesia circuit for treating bronchospasm.