Utilization of UV absorbance for estimation of phosphate elimination during hemodiafiltration

Per Enberg1, Ivo Fridolin, Jana Holmar

  • 1Department of Nephrology UHL, County Council of Östergötland, Linköping, Sweden. peren335@student.liu.se

Abstract

Related Concept Videos

Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration01:25

Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration

Hemoperfusion and hemofiltration are critical techniques in medical treatments to eliminate accumulated drugs, metabolites, and electrolytes from the bloodstream. These methods are particularly vital in cases of accidental poisoning and drug overdose.Hemoperfusion involves passing blood through an adsorbent material to remove unwanted substances. The main adsorbents used in hemoperfusion include activated charcoal and Amberlite resins. Activated charcoal can adsorb both polar and nonpolar...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate01:25

Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate

The glomerular filtration rate (GFR) is a critical indicator of kidney health, reflecting how well the kidneys filter blood. Changes in GFR can signal potential kidney impairment, necessitating accurate measurement methods to monitor kidney function effectively.Various molecules can serve as markers for GFR measurement, with the ideal marker meeting several specific criteria. It must freely filter at the glomerulus, avoid reabsorption or secretion by the renal tubules, remain unmetabolized, not...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa01:22

Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa

The pH of urine, the drug's pKa, and the urine flow rate are vital parameters for drug reabsorption and excretion. Urinary pH varies between 4.6 and 8.0 and is influenced by diet, drug intake, and the patient's pathophysiology. It affects a drug's ionization state and reabsorption. For instance, carbohydrate-rich food produces alkaline urine promoting drug excretion, while proteins and certain medications like ascorbic acid lead to acidic urine enhancing reabsorption.
The pKa of a drug,...
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
Phosphate Buffer01:22

Phosphate Buffer

The phosphate buffer system is a critical biological mechanism for maintaining pH stability in the body. This system operates primarily through two components: sodium dihydrogen phosphate (NaH2PO4), which acts as a weak acid, and sodium hydrogen phosphate (Na2HPO4), which serves as a weak base.
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...