Related Experiment Video
Updated: May 17, 2026

Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
Published on: December 2, 2014
Advancements in pressure-volume catheter technology - stress remodelling after infarction
James E Clark1, Michael S Marber
1Department of Cardiology, King's College London, British Heart Foundation Excellence Centre, 4th Floor Lambeth Wing, St Thomas' Hospital, London SE1 7EH, UK. james.2.clark@kcl.ac.uk
Abstract:
Microconductance catheters have been successfully applied to measure left ventricular (LV) function in the mouse to assess cardiac or pharmacological interventions for a number of years. New complex admittance methods produce an estimate of the parallel admittance of cardiac muscle that can be used to correct the measurement in real time. This contrasts with existing conductance technologies that require in vivo calibration using a bolus of hypertonic saline. Here, we report the application of this emerging technology in the context of myocardial infarction and LV remodelling. Using a combination of high-resolution ultrasound and LV conductance catheters, we compared measures of LV function using an admittance system and a traditional conductance-derived pressure-volume (PV) system. We subjected C57BL/6 mice to focal myocardial ischaemia-reperfusion by transient ligation of the left anterior descending coronary artery and assessed cardiac function with different systems to determine the reliability and accuracy of these methods to distinguish between normal and dysfunctional ventricle. We demonstrate that the admittance PV system, in our hands, provides a straightforward solution for assessing LV function in mice. Using this technique in combination with other established methods, we measured LV dysfunction following coronary artery occlusion and reperfusion, which can be ameliorated using a known preconditioning agent (CORM-3), and found that functional read-outs are representative of other methods. We have found that, especially in diseased tissue, LV pressure-volume loops derived from complex admittance provide a reproducible and reliable method of determining LV function without the need for technically challenging calibration. Our data suggest that admittance records accurate/physiological LV cavity volumes when compared with other invasive methods in the same animal. This emerging technology is both effective and reproducible for measuring LV function and dysfunction in the mouse, without the need for complicated interventions to calibrate the measurements or training in a new technology. This may mark the way towards a fast and accurate assessment of murine cardiac function in normal animals and disease models.
More Related Videos
07:28Real-time Pressure-volume Analysis of Acute Myocardial Infarction in Mice
Published on: July 2, 2018
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023