Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Bioelectronic interface for real-time brain biomarker analysis.

Bioelectrochemistry (Amsterdam, Netherlands)·2026
Same author

Safe and Efficient CRISPR Genome Editing of Primary Human T Cells Using a Droplet-Based Cell Mechanoporation Platform.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Sustainable Biointerfaces in Wearable Sensors: Engineered Biopolymers for Continuous Health Surveillance and Diagnostics.

ACS applied bio materials·2026
Same author

Molecularly imprinted polymers as emerging engineered platforms for precision molecular sensing.

Biomaterials science·2026
Same author

Software assisted personalized transduction platform for serum biomarker detection based on electrochemically engineered Cr-MOF - graphene oxide nanohybrid.

Mikrochimica acta·2026
Same author

Mussel-Extracted Byssal Threads as Inspired Biomaterials for Biosensor Fabrication and Biomedical Applications.

ACS biomaterials science & engineering·2026
Same journal

Structural Hairpin Anchoring-Mediated TtAgo Activity Regulation for Programmable Biosensing.

Analytical chemistry·2026
Same journal

Digital Revitalization of a Legacy Linear Ion Trap System.

Analytical chemistry·2026
Same journal

An Interface-Regulated Electrochemical Biosensing Platform Based on the Cascade Amplification of Primer Exchange Reaction and CRISPR/Cas12a for Noninvasive Bladder Cancer Diagnosis.

Analytical chemistry·2026
Same journal

Spatially Resolved Diffusion NMR for Structurally Heterogeneous Materials.

Analytical chemistry·2026
Same journal

Direct Whole-Blood Multiplexing of Small Molecules via a Micelle-Enhanced Chemiluminescent Paper Sensor with Mesoporous Silica Membrane.

Analytical chemistry·2026
Same journal

Modeling the Effects of Short-Range Randomness in Packed Sphere Beds.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: May 17, 2026

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

A simple separation method with a microfluidic channel based on alternating current potential modulation.

Hui-Bog Noh1, Pranjal Chandra, You-Jeong Kim

  • 1Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan 609-735, South Korea.

Analytical Chemistry
|October 19, 2012
PubMed
Summary
This summary is machine-generated.

A novel electrochemical potential modulated microchannel (EPMM) device offers enhanced separation and detection for endocrine disruptors and heavy metal ions. This innovative system achieves high sensitivity and efficiency, demonstrating its effectiveness in real-world sample analysis.

More Related Videos

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
08:06

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone

Published on: February 23, 2017

Related Experiment Videos

Last Updated: May 17, 2026

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
08:06

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone

Published on: February 23, 2017

Area of Science:

  • Analytical Chemistry
  • Electrochemistry
  • Microfluidics

Background:

  • Microfluidic devices are crucial for chemical analysis.
  • Efficient separation and detection of analytes like endocrine disruptors (EDs) and heavy metal ions (HMIs) remain challenging.
  • Existing methods often require complex sample preparation or lack sensitivity.

Purpose of the Study:

  • To develop and characterize a novel electrochemical potential modulated microchannel (EPMM) device for enhanced separation and detection.
  • To investigate the performance of the EPMM device using EDs and HMIs as model analytes.
  • To optimize analytical parameters for improved separation efficiency and detection limits.

Main Methods:

  • Development of an EPMM device utilizing screen-printed carbon electrodes.
  • Application of alternating current (AC) potential to microchannel walls for analyte manipulation.
  • Systematic study of AC amplitude, frequency, flow rate, buffer concentration, pH, detection potential, and temperature.
  • Evaluation of separation efficiency using theoretical plate number, retention time, and half-peak width.

Main Results:

  • The EPMM device successfully separated and detected EDs and HMIs.
  • Optimized parameters led to increased effective concentration and sharp flow fronts.
  • Achieved linear calibration ranges from 0.15 to 250.0 nM for EDs (LOD 86.4 ± 2.9 pM) and 0.01 to 10.0 nM for HMIs (LOD 9.5 ± 0.3 pM).
  • Demonstrated successful application with authentic and real-world samples.

Conclusions:

  • The EPMM device provides a simple, effective, and sensitive platform for the separation and detection of target analytes.
  • The developed system shows significant potential for environmental monitoring and chemical analysis.
  • This technology offers a promising advancement in microfluidic-based analytical systems.