Approximation error method can reduce artifacts due to scalp blood flow in optical brain activation imaging
Related Experiment Video
Updated: May 17, 2026

Best Current Practice for Obtaining High Quality EEG Data During Simultaneous fMRI
Published on: June 3, 2013
Juha Heiskala1, Ville Kolehmainen, Tanja Tarvainen
1University College London, Department of Computer Science, Gower Street, London WC1E 6BT, United Kingdom. j.heiskala@cs.ucl.ac.uk
Abstract:
Diffuse optical tomography can image the hemodynamic response to an activation in the human brain by measuring changes in optical absorption of near-infrared light. Since optodes placed on the scalp are used, the measurements are very sensitive to changes in optical attenuation in the scalp, making optical brain activation imaging susceptible to artifacts due to effects of systemic circulation and local circulation of the scalp. We propose to use the Bayesian approximation error approach to reduce these artifacts. The feasibility of the approach is evaluated using simulated brain activations. When a localized cortical activation occurs simultaneously with changes in the scalp blood flow, these changes can mask the cortical activity causing spurious artifacts. We show that the proposed approach is able to recover from these artifacts even when the nominal tissue properties are not well known.
More Related Videos
11:00Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017