Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Resolving fluorescently labeled species using highly multiplexed spectral FLIM.

Scientific reports·2026
Same author

Targeting secreted PLA<sub>2</sub> interactions with EGFR and vimentin to arrest prostate tumour growth.

Cell death & disease·2025
Same author

ESPRESSO: spatiotemporal omics based on organelle phenotyping.

Nature methods·2025
Same author

Highly multiplexed spectral FLIM via physics informed data analysis.

bioRxiv : the preprint server for biology·2025
Same author

Exploiting the detector distance information in image scanning microscopy by phasor-based SPLIT-ISM.

Biomedical optics express·2025
Same author

Fluorescence Lifetime Imaging Detects Long-Lifetime Signal Associated with Reduced Pyocyanin at the Surface of <i>Pseudomonas aeruginosa</i> Biofilms and in Cross-Feeding Conditions.

ACS infectious diseases·2025

Related Experiment Video

Updated: May 17, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

Digital parallel frequency-domain spectroscopy for tissue imaging.

Cosimo Arnesano1, Ylenia Santoro, Enrico Gratton

  • 1University of California Irvine, Biomedical Engineering Department, Laboratory for Fluorescence Dynamics, Irvine, California, USA.

Journal of Biomedical Optics
|October 23, 2012
PubMed
Summary
This summary is machine-generated.

A new method improves near-infrared optical property measurements in turbid media. It uses parallel frequency acquisition and a white laser for faster, more accurate, and noninvasive analysis of scattering-corrected absorption spectra.

More Related Videos

Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation
14:21

Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation

Published on: January 22, 2013

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

Related Experiment Videos

Last Updated: May 17, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
11:05

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology

Published on: January 21, 2015

Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation
14:21

Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation

Published on: January 22, 2013

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

Area of Science:

  • Biomedical Optics
  • Photon Migration Imaging
  • Turbid Media Characterization

Background:

  • Near-infrared (NIR) optical properties of turbid media are crucial for noninvasive analysis.
  • Conventional frequency-domain photon migration (FDPM) techniques have limitations in data acquisition speed and wavelength range.
  • Existing methods struggle with accurate broadband NIR scattering-corrected absorption spectra.

Purpose of the Study:

  • To develop an improved method for quantifying NIR optical properties of turbid media.
  • To enhance the accuracy and efficiency of FDPM measurements.
  • To enable noninvasive broadband NIR scattering-corrected absorption spectra acquisition.

Main Methods:

  • Introduced digital parallel acquisition of a frequency comb.
  • Utilized a single white laser source for both frequency-domain (FD) and steady-state (SS) measurements.
  • Implemented all-digital acquisition to minimize noise and interference.

Main Results:

  • Achieved faster data acquisition through parallel processing compared to serial scanning.
  • Enabled higher penetration depth with low laser power due to high source brightness.
  • Eliminated analog noise and radiofrequency interference through all-digital acquisition.

Conclusions:

  • The developed method offers significant improvements in acquiring optical parameters for turbid media.
  • This technique provides a more efficient and accurate approach to measure NIR scattering-corrected absorption spectra.
  • The enhanced FDPM method holds promise for advanced noninvasive biomedical optical analysis.