Optical performance of coherent and incoherent imaging systems in the presence of ghost images
Rania H Abd El-Maksoud1, Matthias Hillenbrand, Stefan Sinzinger
1Technische Universität Ilmenau, IMN MacroNano, Fachgebiet Technische Optik, Ilmenau, Germany. rania_abdelmaksoud@sci.asu.edu.eg
Abstract:
Ghost image analysis is of interest for optical designers as ghost images may degrade image quality in imaging systems. In a previous paper by Abd El-Maksoud and Sasian [Appl. Opt. 50, 2305 (2011)10.1364/AO.50.002305], ghost image analysis for incoherent systems was evaluated using geometrical optics. Some criteria were presented to identify focused ghost images at the nominal image plane. The main goal of this paper is to provide a conceptual understanding of ghost image formation and its impact on the performance of imaging systems using wave theory and Fourier optics. To achieve this goal, a methodology is developed to model ghost images after considering diffraction effects. Expressions for the ghost diffraction point spread function and the ghost transfer function are presented. These functions are used to construct effective point spread and effective transfer functions. To provide insights on the developed theory, some simulation examples are provided and discussed.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...