Automatic bone removal technique in whole-body dual-energy CT angiography: performance and image quality
Boris Schulz1, Katharina Kuehling, Wolfgang Kromen
1Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23 C UG, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany. boris.schell@googlemail.com
Objective:
The purpose of this study was to evaluate the efficiency of automatic bone removal in dual-energy CT angiography (CTA) of the trunk.
Subjects And Methods:
Nineteen patients underwent dual-energy CTA of the trunk (tube A, 140 kV; tube B, 100 kV). In addition to the dual-energy dataset, an image equivalent to that of a standard 120-kV single-energy examination was generated with both tubes. Automated bone segmentation was performed on both datasets, and the results were analyzed. The time required for and subjective image quality of the maximum intensity projections (MIPs) generated were evaluated.
Results:
Errors in bone segmentation were found for 1.5% of bones on dual-energy images and 12.4% of bones on single-energy images (p < 0.01). The most important differences were found in the rib cage, sternum, and pelvis. The times required for postprocessing of MIPs were similar for the dual-energy (113.5 seconds) and single-energy (106.8 seconds) techniques. The subjective image quality of the arteries was considered better for dual-energy CTA (4.5 points) than for single-energy CTA (4.1 points) owing to false cutoff of vessels during the bone removal process on the single-energy images (p = 0.026).
Conclusion:
For CTA of the trunk, the dual-energy postprocessing capabilities for 3D visualization are superior to the threshold-based bone removal of single-energy CT. Dual-energy CTA can generate boneless MIP images of substantial quality.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...