Degradation Pathway for Eplerenone by Validated Stability Indicating UP-LC Method
Kondru Sudhakar Babu1, Venkataramanna Madireddy, Venkata Somaraju Indukuri
1Department of Chemistry, Sri Krishnadevaraya University, Anantapur 515003, Andhra Pradesh 515003, India.
Abstract:
Degradation pathway for eplerenone is established as per ICH recommendations by validated and stability-indicating reverse phase liquid chromatographic method. Eplerenone is subjected to stress conditions of acid, base, oxidation, and thermal and photolysis. Significant degradation is observed in acid and base stress conditions. Four impurities are studied and the major degradant (RRT about 0.31) was identified by LC-MS and spectral analysis. The stress samples are assayed against a qualified reference standard and the mass balance is found close to 99.5%. Efficient chromatographic separation is achieved on a Waters symmetry C18 stationary phase with simple mobile phase combination delivered in gradient mode and quantification is carried at 240 nm at a flow rate of 1.0 mL min(-1). In the developed LC method the resolution between eplerenone and four potential impurities (imp-1, imp-2, imp-3, and imp-4) is found to be greater than 4.0. Regression analysis shows an r value (correlation coefficient) of greater than 0.999 for eplerenone and four potential impurities. This method is capable to detect the impurities of eplerenone at a level of 0.020% with respect to test concentration of 1.0 mg mL(-1) for a 20 μL injection volume. The developed UPLC method is validated with respect to specificity, linearity and range, accuracy, precision, and robustness for impurities and assay determination.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...