Lack of precision in HbA(1c) values on variant II in cases of hemoglobin Q India

P K Nigam1, S Sharma, R Sareen

  • 1Dr Lal PathLabs Pvt Ltd, 'ESKAY HOUSE', 54, Hanuman Road, 110001 New Delhi, India.

This study was carried out to check the precision of HbA(1c) values on Bio-Rad Variant II in cases of a rare hemoglobin variant Q India. The study was carried out over a three month period on samples collected for HbA(1c) estimation. Seven out of eleven patients showed variable results of HbA(1c) with a very high and unacceptable intraday mean coefficient of variation (CV) of 9.93%. We conclude, that the results of HbA(1c) on Variant II can not be reported without adversely affecting HbA(1c) as a marker of long-term glycemic control in patients who have hemoglobin Q India. The HbA(1c) value of these patients needs to be assessed by a different instrument/method or the glycemic control be monitored by an alternate test like serum Fructosamine.

Related Concept Videos

Type II Diabetes Mellitus III: Clinical Manifestations and Diagnosis01:25

Type II Diabetes Mellitus III: Clinical Manifestations and Diagnosis

Type 2 diabetes mellitus develops gradually and is often asymptomatic in early stages.Clinical ManifestationsWhen symptoms appear, they include fatigue, blurred vision, pruritus, delayed wound healing, and recurrent infections, particularly candidal infections. Peripheral neuropathy may present as numbness or tingling in the extremities. Classic hyperglycemia symptoms—polyuria, polydipsia, and polyphagia—are less common. Most patients are overweight and frequently have associated hypertension...
Multiple Allele Traits01:49

Multiple Allele Traits

The Concept of Multiple Allelism
Hyperglycemia01:29

Hyperglycemia

Hyperglycemia is an abnormally high blood glucose level. It is diagnosed by fasting glucose ≥126 mg/dL, 2-hour oral glucose tolerance test (or OGTT) ≥200 mg/dL, random glucose ≥200 mg/dL with symptoms, or HbA1c ≥6.5%. However, HbA1c results may be unreliable in certain conditions, such as anemia or hemoglobinopathies, and the diagnosis should be confirmed unless classic symptoms are present. Postprandial hyperglycemia is typically considered significant when glucose levels exceed 180 mg/dL two...
Variability: Analysis01:11

Variability: Analysis

Measures of variability are statistical metrics that reveal the dispersion pattern within a dataset. They are pivotal in biostatistics, providing insights into the heterogeneity within health and biological data. Variability signifies the degree to which data points diverge from one another, helping researchers understand the potential range of values and associated uncertainty within the data.
The range is a simple measure of variability, indicating the difference between the highest and...
Accuracy and Errors in Hypothesis Testing01:13

Accuracy and Errors in Hypothesis Testing

Hypothesis testing is a fundamental statistical tool that begins with the assumption that the null hypothesis H0 is true. During this process, two types of errors can occur: Type I and Type II. A Type I error refers to the incorrect rejection of a true null hypothesis, while a Type II error involves the failure to reject a false null hypothesis.
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5% chance...
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...