Related Experiment Video
Updated: May 17, 2026

05:31
Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
The dual radius hemispherical 'Trident" cup: results based on 150 consecutive cases.
Enrico Bonicoli1, Alessandro Baluganti, Lorenzo Andreani
1First Department of Orthopaedics, University of Pisa, Italy.
Surgical Technology International
|October 31, 2012
Summary
The Trident dual-radius cup provides excellent initial stability and bony incorporation in total hip replacements. This acetabular component demonstrates a valid choice for hip replacement surgery, showing no signs of loosening or radiolucency.
Area of Science:
- Orthopedic Surgery
- Biomaterials Engineering
- Medical Device Design
Background:
- Achieving initial stability in press-fit acetabular cups is crucial for successful total hip replacement (THR).
- Dual-radius press-fit cups, with a larger equatorial diameter, offer a method to enhance press-fit and ensure stability for bone ingrowth.
- Various techniques like line-to-line fit and screw fixation exist, but dual-radius designs aim for reliable initial stability.
Purpose of the Study:
- To evaluate the clinical performance and initial stability of the dual-radius Trident AD acetabular shell in primary total hip replacements.
- To assess the bony incorporation and radiographic evidence of loosening or radiolucency of the Trident cup.
- To determine if the Trident cup is a suitable option for acetabular replacement surgery.
Main Methods:
- A retrospective review of the first 150 consecutive primary total hip replacements (THRs) using the Trident AD shell (Stryker Orthopaedics) was conducted.
- The study period was from January 2002 to January 2008.
- Data collected included patient follow-up duration, post-operative Harris Hip Scores, and radiographic assessments for bony incorporation and loosening.
Main Results:
- The median follow-up duration was 6.2 years (range, 5-7 years).
- The median post-operative Harris Hip Score was 90.5 (range, 51-98).
- All components showed bony incorporation, with no definite radiographic loosening or signs of radiolucency at the latest follow-up.
Conclusions:
- The Trident dual-radius acetabular cup demonstrates encouraging results in primary total hip replacement.
- The component achieved reliable initial stability and excellent bony incorporation.
- The Trident cup is considered a valid and effective choice for acetabular replacement, with no evidence of mechanical failure within the study period.