Related Experiment Video
Updated: May 17, 2026

A Flow-through Exposure System for Evaluating Suspended Sediments Effects on Aquatic Life
Published on: January 9, 2017
A subjective evaluation of a drinking system for saturation divers
1Senior scientist at Norwegian Underwater Invention, NUI AS, Gravdalsveien 245, P.O.Box 23 Ytre Laksevaag, N-5848 Bergen Norway, Phone: +47 55942839,
Abstract:
Studies have shown that divers may lose large volumes of body fluids in hot water suit (HWS) dives lasting for four hours or longer, and that this dehydration is mainly caused by sweating. Body fluid balance may be impaired and the diver's alertness and power of judgement could be influenced by such imbalance. The main objective of the present study was to obtain a subjective judgement of a drinking system for divers (DSFD) and to obtain information related to body fluid loss during long saturation lock-out dives. Via a suction pipe imbedded in the microphone unit in the oronasal mask, the DSFD makes it possible for the diver to drink while in the water. Ten divers tested the drinking system during 12 saturation lock-out dives lasting on average for 5.5 h. A questionnaire was answered after each dive. The divers drank 21 times (range 5-30 times) during the dives, and the average drinking volume was 1.4 litre (range 1.0-1.5 litre) but only drank 0.04 litre (range 0-0.3 litre) in the bell after diving. The system was easy to operate and preparation and clothing did not cause any delay. The suction pipe did not intrude and the microphone performed excellently. The work in water was not hindered by DSFD and all divers were very satisfied with the drinking system. It was obvious that the need for fluid intake after a dive with DSFD was markedly reduced; another good indication of maintained body fluid balance.
More Related Videos
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
09:22Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus (SCUVA)
Published on: October 31, 2011
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...