Array Tomography Workflow for the Targeted Acquisition of Volume Information using Scanning Electron Microscopy
Published on: July 15, 2021
TAVI 2012: state of the art
Jochen Reinöhl1, Constantin von Zur Mühlen, Martin Moser
1Department of Cardiology, Heart Center Freiburg University, Hugstetter Str. 55, 79106, Freiburg, Germany. jochen.reinoehl@universitaets-herzzentrum.de
Abstract:
The development of "transcatheter aortic valve implantation (TAVI)" is changing the field of cardiovascular medicine rapidly. The basic principle of TAVI is the percutaneous implantation of a bioprosthesis mounted in a metal frame. The prosthesis, which is attached to the tip of the catheter, is positioned in the native aortic valve and expanded. The first successful implantation was made by Alain Cribier in 2002. Several smaller mono- and multicenter studies later confirmed the technical feasibility of this procedure. Its true value as an important, therapeutic alternative to open heart surgery in inoperable and high-risk patients is now confirmed in large multicenter registries and by the prospective, randomized PARTNER trial. Decisive for the future acceptance of the procedure and for a possible expansion of the indication spectrum will be (1) continuous further development of the implantation technique and the prosthesis design, (2) reduction of TAVI-associated complications, (3) confirmation of the initial positive long-term results and (4) confirmation of the promising results in the treatment of surgical prosthesis dysfunctions and of patients with low to intermediate risk.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
10:10Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging
Published on: January 30, 2026
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
The Retina
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Latitudes and Departures
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET