Silicon isotope ratios affected by sodium-induced broadband interference in high resolution multicollector-ICPMS
Axel Pramann1, Olaf Rienitz, Detlef Schiel
1Physikalisch-Technische Bundesanstalt, Braunschweig, Germany. axel.pramann@ptb.de
Abstract:
The measurement of isotope ratios of silicon highly enriched in (28)Si ("Si28", x((28)Si) > 99.99%) is influenced by a significant interference (20%) on the (30)Si(+) signal when using a cup configuration of C ((29)Si(+)) and H3 ((30)Si(+)) on a Neptune MC-ICPMS. This interference was observed in silicon solutions with aqueous NaOH (w(NaOH) > 0.001 g/g) and in highly concentrated aqueous NaOH blank solutions (e.g., w(NaOH) = 0.25 g/g) but never in KOH solutions. By redirecting the ions, the interference was detected with all other Faraday cups except the center cup. The interference can be explained by ion scattering induced by the presence of large amounts of sodium. Due to its shielded location, these stray ions were not detected in the center cup. This effect explains an anomalous increase of the abundance of the (30)Si(+) signal in (30)Si/(29)Si isotope ratio measurements made using aqueous NaOH blank solutions with w(NaOH) ≥ 0.001 g/g. For silicon isotopic measurements, it is recommended to use alkaline solutions for sample dissolution and dilution that do not contain sodium. The effects of this interference are extremely important for the experimental determination of the Avogadro constant N(A) using the "silicon sphere approach". It can also have a significant effect on Si isotope analyses in matrices with a naturally high concentration of sodium (e.g., seawater).
More Related Videos
07:103D Depth Profile Reconstruction of Segregated Impurities Using Secondary Ion Mass Spectrometry
Published on: April 29, 2020
11:50Metal-silicate Partitioning at High Pressure and Temperature: Experimental Methods and a Protocol to Suppress Highly Siderophile Element Inclusions
Published on: June 13, 2015
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Isotope Effect
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Emission Spectroscopy: Lab