Related Experiment Video
Updated: May 16, 2026

Digital Planimetry for Assessing Wound Closure Kinetics in a Mouse Model
Published on: January 10, 2025
A novel and accurate technique of photographic wound measurement
Rahul Shetty1, H Sreekar, Shashank Lamba
1Department of Plastic and Reconstructive Surgery, Christian Medical College, Vellore, Tamil Nadu, India.
Context:
Wound measurement is an important aspect of wound management. Though there are many techniques to measure wounds, most of them are either cumbersome or too expensive.
Aims:
To introduce a simple and accurate technique by which wounds can be accurately measured.
Settings And Design:
This is a comparative study of 10 patients whose wounds were measured by three techniques, i.e. ruler, graph and our technique.
Materials And Methods:
The graph method was taken as the control measurement. The extent of deviation in wound measurements with our method was compared with the standard technique. The statistical analysis used was ANOVA.
Results:
The ruler method was highly inaccurate and overestimated the wound size by nearly 50%. Our technique remained consistent and accurate with the percentage of over or underestimation being 2-4% in comparison with the graph method.
Conclusions:
This technique is simple and accurate and is an inexpensive and non-invasive method to accurately measure wounds.