Related Experiment Video
Updated: May 16, 2026

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
Published on: January 10, 2019
Macular imaging for glaucoma using spectral-domain optical coherence tomography: a review
Jessica J Wong1, Teresa C Chen, Lucy Q Shen
1Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Glaucoma Service, Harvard Medical School, Boston, MA, USA. Jessica.J.Wong@gmail.com
Spectral-domain optical coherence tomography (SD-OCT) shows promise for glaucoma diagnosis using macular thickness parameters. These measurements offer diagnostic sensitivity comparable to traditional peripapillary retinal nerve fiber layer (pRNFL) assessments.
Area of Science:
- Ophthalmology
- Medical Imaging
- Glaucoma Research
Background:
- Optical coherence tomography (OCT) is crucial for glaucoma detection and monitoring, with peripapillary retinal nerve fiber layer (pRNFL) measurements historically favored.
- Earlier time-domain OCT (TD-OCT) studies limited the use of macular thickness parameters in glaucoma due to inferior diagnostic performance compared to pRNFL.
- The development of spectral-domain OCT (SD-OCT) has enhanced macular imaging capabilities, enabling better segmentation and measurement of individual retinal layers.
Purpose of the Study:
- To review recent studies investigating the diagnostic ability, reproducibility, and limitations of macular SD-OCT parameters in glaucoma.
- To assess the current clinical utility of macular SD-OCT for glaucoma diagnosis and management.
Main Methods:
- Systematic review of recent scientific literature focusing on SD-OCT macular parameters in glaucoma.
- Analysis of studies evaluating diagnostic accuracy, reproducibility, and limitations of these novel imaging parameters.
- Comparison of SD-OCT macular parameter performance against established OCT methods (TD-OCT and pRNFL).
Main Results:
- SD-OCT demonstrates superior reproducibility compared to TD-OCT for macular imaging.
- While some conflicting reports exist, the majority of studies indicate that SD-OCT macular parameters offer diagnostic sensitivity at least comparable to TD-OCT and other SD-OCT parameters.
- Recent research highlights the growing potential of SD-OCT macular imaging in glaucoma assessment.
Conclusions:
- Macular imaging using SD-OCT is a rapidly evolving area with significant potential in glaucoma diagnosis.
- SD-OCT macular parameters show comparable diagnostic sensitivity to established OCT methods, offering a valuable addition to glaucoma assessment.
- Further research is warranted to fully elucidate the role and optimize the application of SD-OCT macular parameters in clinical practice.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment

