Beat-to-beat vectorcardiographic analysis of ventricular depolarization and repolarization in myocardial infarction
Muhammad A Hasan1, Derek Abbott, Mathias Baumert
1School of Electrical & Electronic Engineering, The University of Adelaide, Adelaide, Australia.
Objectives:
Increased beat-to-beat variability in the QT interval has been associated with heart disease and mortality. The purpose of this study was to investigate the beat-to-beat spatial and temporal variations of ventricular depolarization and repolarization in vectorcardiogram (VCG) for characterising myocardial infarction (MI) patients.
Methods:
Standard 12-lead ECGs of 84 MI patients (22 f, 63±12 yrs; 62 m, 56±10 yrs) and 69 healthy subjects (17 f, 42±18 yrs; 52 m, 40±13 yrs) were investigated. To extract the beat-to-beat QT intervals, a template-matching algorithm and the singular value decomposition method have been applied to synthesise the ECG data to VCG. Spatial and temporal variations in the QRS complex and T-wave loops were studied by investigating several descriptors (point-to-point distance variability, mean loop length, T-wave morphology dispersion, percentage of loop area, total cosine R-to-T).
Results:
Point-to-point distance variability of QRS and T-loops (0.13±0.04 vs. 0.10±0.04, p< 0.0001 and 0.16±0.07 vs. 0.13±0.06, p< 0.05) were significantly larger in the MI group than in the control group. The average T-wave morphology dispersion was significantly higher in the MI group than in the control group (62°±8° vs. 38°±16°, p< 0.0001). Further, its beat-to-beat variability appeared significantly lower in the MI group than in the control group (12°±5° vs. 15°±6°, p< 0.005). Moreover, the average percentage of the T-loop area was found significantly lower in the MI group than the controls (46±17 vs. 55±15, p< 0.001). Finally, the average and beat-to-beat variability of total cosine R-to-T were not found statistically significant between both groups.
Conclusions:
Beat-to-beat assessment of VCG parameters may have diagnostic attributes that might help in identifying MI patients.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias