Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Two-Dimensional Microscopy in Microbiology01:29

Two-Dimensional Microscopy in Microbiology

Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ten questions with …. Robert M Dondelinger.

Biomedical instrumentation & technology·2013
Same author

Gas chromatography systems.

Biomedical instrumentation & technology·2012
Same author

The fundamentals of ...liquid chromatography systems.

Biomedical instrumentation & technology·2012
Same author

Radiation.

Biomedical instrumentation & technology·2012
Same author

The fudamental of ... cell washing centrifuges.

Biomedical instrumentation & technology·2012
Same author

The fundamentals of... apnea monitors.

Biomedical instrumentation & technology·2011
Same journal

Improving Sterile Processing Operational Efficiency through Organizational Change.

Biomedical instrumentation & technology·2026
Same journal

Detecting Secondary Medication Infusion Errors via Spectrophotometry.

Biomedical instrumentation & technology·2026
Same journal

Inactivation of Endotoxin by Moist Heat, Electron Beam, and Gamma Irradiation.

Biomedical instrumentation & technology·2026
Same journal

Biological Indicators and Process Challenge Devices for Nitrogen Dioxide Sterilization.

Biomedical instrumentation & technology·2026
Same journal

Laparoscopic Instrument Defect Detection: A Prospective, Multisite Study.

Biomedical instrumentation & technology·2026
Same journal

Impact of Leadership Structures on Sterile Processing Performance and Patient Safety.

Biomedical instrumentation & technology·2026
See all related articles

Related Experiment Video

Updated: May 16, 2026

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy
09:46

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy

Published on: January 17, 2018

Electron microscopes

Robert M Dondelinger1

  • 1US Military Entrance Processing Command, North Chicago, IL, USA. dondelinger@mepcom.army.mil

Biomedical Instrumentation & Technology
|November 23, 2012
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Correlative Light and Electron Microscopy (CLEM) as a Tool to Visualize Microinjected Molecules and their Eukaryotic Sub-cellular Targets
09:10

Correlative Light and Electron Microscopy (CLEM) as a Tool to Visualize Microinjected Molecules and their Eukaryotic Sub-cellular Targets

Published on: May 4, 2012

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography
14:56

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography

Published on: May 20, 2022

Related Experiment Videos

Last Updated: May 16, 2026

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy
09:46

A Method for Obtaining Serial Ultrathin Sections of Microorganisms in Transmission Electron Microscopy

Published on: January 17, 2018

Correlative Light and Electron Microscopy (CLEM) as a Tool to Visualize Microinjected Molecules and their Eukaryotic Sub-cellular Targets
09:10

Correlative Light and Electron Microscopy (CLEM) as a Tool to Visualize Microinjected Molecules and their Eukaryotic Sub-cellular Targets

Published on: May 4, 2012

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography
14:56

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography

Published on: May 20, 2022